You called because something stopped working. Maybe a breaker won't reset. Maybe half your villa went dark at 11pm on a Friday. Whatever it is — our DEWA-approved engineers come with proper instruments, not guesswork. We find the fault first, fix it second, and we don't leave until every circuit we touched has been tested and you have a signed document in hand.
Speed when you need it, engineers who are actually accountable, and a price you know before anyone picks up a tool. That's what we built this service around.
We quote before we start — always. The figures below are starting rates. Your exact cost depends on the load assessment, cable run length, and materials needed. No surprise charges after. Same rate day or night.
| Service | What's Included | Starting From |
|---|---|---|
| Electrical Site Inspection | Full safety check, load assessment, written report | AED 150 |
| DB Box Dressing | Cable management, MCB sizing, circuit labelling, thermal scan | AED 350 |
| MCB / RCD / RCBO Replacement | Rated breaker swap with loop impedance test after | AED 120 |
| Socket / Outlet Replacement | BS 1363 13A socket with child-safe shutter, earth verified | AED 80 |
| LED Lighting Installation | Per downlight — wiring, driver, and fitting all included | AED 60 |
| Partial Villa Rewiring (per room) | New conduit, cable pull, terminations, IR test per circuit | AED 900 |
| Full Villa Rewiring | Load calc, phased rewire, new DB, DEWA sign-off docs | AED 4,500 |
| Emergency Short-Circuit Repair | 15-min structured diagnosis + fault repair, tested before leaving | AED 200 |
| DEWA Smart Meter Troubleshooting | Phase-loss diagnosis, tamper alarm clearance, bypass faults | AED 250 |
| Thermal Imaging Scan | Infrared scan of live DB and cables, written report | AED 400 |
| Earthing System Installation | Earth rod, bonding conductors, electrode resistance test | AED 600 |
| Phase Balancing (3-Phase) | Clamp-meter load per phase, circuit redistribution, re-test | AED 450 |
| EV Home Charger Installation | 7kW Type 2, dedicated 32A circuit, Type A RCD, DEWA approval | AED 800 |
* Starting rates. VAT included. Site survey required for rewiring jobs. Same rate 24 hours — no after-hours surcharge. Call 0554689815 for a site-specific quote.
Not sure what service you actually need? Just describe what's happening on the phone — our engineer will tell you exactly what applies before you commit to anything.
Free Phone ConsultationFive core service areas — each explained with enough detail that you know what you're actually getting, why it matters, and what corners some people cut that we don't.
Most Dubai villas built before 2010 were designed for 15–20kVA of connected load. Then you add three inverter AC units, a dishwasher, washing machine, induction hob, and a home cinema — and you're well past what those original 2.5mm² cables were ever specified for. This isn't a scare tactic; it's just physics.
Before we pull a single metre of new cable, our engineer runs a proper electrical load audit. We calculate your total connected load, apply BS 7671 diversity factors, and size cables to handle today's demand with 30% headroom for what you'll add in three years.
Full villa rewiring from AED 4,500. Site survey is always free first.
Book SurveyOpen the distribution board in the average Dubai apartment put together by a lowest-bid contractor, and here's what you'll find: cables with no labels, MCBs grabbed off the shelf without checking the downstream cable rating, terminations tightened by hand. We've come across DB boards where an unlabelled breaker was controlling the main AC unit and was rated at double the cable's current capacity. That's not a minor issue — that's a cable that'll overheat before the breaker trips.
A 32A MCB on a 2.5mm² cable is a fire waiting to happen. That cable carries 20A maximum in typical Dubai conduit. The breaker won't trip until the cable is already overheating. We check every breaker against its downstream cable size and swap anything that's wrong — no exceptions, no "it'll probably be fine."
One 30mA RCD covering an entire floor looks cheap on a materials list. But one leaky washing machine trips the whole board and kills the fridge at 3am. We fit individual RCBOs on high-risk circuits — bathrooms, kitchens, laundry rooms — so a single fault doesn't cascade across the whole property.
Every way gets an engraved label — not a sticker that peels off in Dubai's heat by next summer. We produce a typed circuit schedule, laminate it, and fix it inside the board door. Your tenant, property manager, or the next electrician can identify any circuit in under 30 seconds without calling anyone.
We scan the board with a FLIR E8 Pro camera while it's under real load. A hot termination shows orange before it becomes a fire hazard. We scan, photograph, log the finding, and fix it on the same visit. You leave with a copy of the thermal report — something to show a property manager or insurer if needed.
DB dressing from AED 350 — includes MCB sizing, circuit labelling, and thermal scan.
Book DB InspectionDEWA's smart meters log voltage, current, power factor, and energy data in real time. When the meter flags a tamper event, phase-loss alarm, or communication fault, DEWA can suspend your supply remotely within minutes. That's not something you fix with a visual check and a reset.
Our DEWA-registered engineers handle new connection applications, NOC requests, and smart meter fault resolution directly with DEWA. We know the inspection checklist and the compliance format they expect — so your application doesn't get rejected over a paperwork technicality and you're not waiting weeks for a re-submission.
DEWA issue blocking your supply? Call directly — we move fast on these.
Call 0554689815
LED selection is about more than wattage. It's choosing the right colour temperature for each room, matching drivers to dimmers so nothing flickers at low levels, and making sure outdoor fittings can handle Dubai's coastal humidity without corroding within a year. Get any one of those three wrong, and no amount of clever furniture arrangement compensates for it.
Bedrooms, living rooms, dining areas. A soft amber-white that's easy on the eyes after sunset and makes skin tones look natural. If you use the space in the evening and want it to feel like a home rather than an office, this is the one.
Kitchens, bathrooms, home offices, garages. Neutral white renders colours accurately — important for food prep, grooming, and reading. Crisp without the harsh clinical feel of 6500K daylight LEDs that people often regret.
Not every LED driver supports TRIAC dimming. Mismatched LED-dimmer combinations produce visible flicker at low levels and audible buzzing from the driver. We match each LED to a compatible dimmer type before buying anything. No flicker, no buzz — guaranteed.
Dubai's humidity demands IP65 minimum for exterior fittings. Pool-surround lighting requires IP68 and must run on SELV low-voltage circuits — mains voltage within 3.5m of water is prohibited under BS 7671 Section 702. We design pool lighting correctly from the first calculation, not as an afterthought.
LED installation from AED 60 per point — wiring, driver, and fitting included.
Get LED Quote
Here's what actually happens during a short circuit: fault current spikes to 3,000–10,000 amps before the MCB clears it. The breaker trips in milliseconds — but the energy released in that window damages cable insulation, destroys socket faces, and can ignite anything touching the fault point. Resetting the breaker without finding the root cause is exactly how house fires start. Please don't do that.
Our emergency process starts with a structured 15-minute diagnosis using Megger MIT430 insulation testers and Fluke 1663 loop impedance meters — not a visual inspection and a best guess. We locate the fault before touching a single connection.
Don't keep resetting the breaker. Call us first — we'll tell you what to do right now.
🚨 Emergency — 0554689815Dubai Municipality enforces both DEWA technical standards and BS 7671 (IET Wiring Regulations 18th Edition). Non-compliant electrical work doesn't just fail inspection — it voids your property insurance and creates direct personal liability if something goes wrong.
The 18th Edition applies to all residential electrical work in Dubai. Here's what we apply on every job — not just the ones we think are high-risk:
All electrical contractors in Dubai need both Dubai Municipality licensing and DEWA contractor registration. Here's what actually happens when you use someone who has neither:
A 1-ohm loose termination carrying 10A generates 100 watts of heat at that one point. That's enough to char surrounding cable insulation over weeks. The MCB won't trip — the fault current isn't high enough to trigger it. The only way to catch it before it becomes a fire is with a calibrated infrared camera on a live board under real load.
We use a FLIR E8 Pro to scan panels and cable runs. Every anomaly gets photographed, logged in a written report, and fixed on the same visit wherever we can manage it. You receive a copy of the report.
Book Thermal Scan — AED 400What thermal imaging finds that visual inspection misses:
The AED 150 you save on a handyman socket job can turn into AED 50,000 in fire remediation or a rejected insurance claim. Here's what the actual difference looks like — tools, process, and documentation, side by side.
Had handyman electrical work done recently? Book a compliance check — we'll tell you exactly what needs fixing and what's safe to leave alone.
Compliance Check — AED 150Every engineer arrives with a professional-grade kit — not the AED 25 consumer multimeter from the hardware shop. Our engineers use Fluke 179 True-RMS multimeters for voltage, current, resistance, and continuity — calibrated annually, accurate to ±0.09% on DC voltage.
For insulation testing we carry Megger MIT430-2 testers generating a certified 500V DC test voltage. A proper IR test at 500V stresses the insulation in a way that mirrors an actual AC voltage surge. A basic continuity tester tells you nothing meaningful about insulation quality — it just confirms the conductor isn't physically broken.
When a circuit breaker is tripping, we measure the actual prospective short-circuit current at the board — typically 1–6kA in Dubai residential supplies — and confirm the installed MCB's breaking capacity exceeds it. That's engineering. And that's the difference between a fix that lasts and one that fails again in two months with a bill attached.
We cover the whole Dubai emirate. These are the communities we're called out to most often. 60-minute response target from time of call — no distance surcharge anywhere in Dubai.
Written by our lead engineers — not copy-pasted from a how-to article. If your question isn't here, call 0554689815 and ask directly. We don't mind.
DEWA-approved engineers. 60-minute target response. Same rate, any time of day or night — no exceptions.